Timer-based drain valves are primarily deployed in application where the condensate generation is predictable and a regular schedule for drainage can be established.
Liquid water collected from 75KW Compressed Air System
FAD: 522cfm, 7 bar(g) discharge pressure, Ambient RH: 65%
Ambient Temperature (°C) | Compressor Discharge Temperature (°C) | Water Vapour Entering The Compressor (Iph) | Liquid Water Removed At The Aftercooler (Iph) | Liquid Water Removed At The Refrigeration Air Dryer (Iph) | Total Liquid Water Collected From Compressed Air System Per Year (L) |
---|---|---|---|---|---|
25
|
32 | 14 | 10 | 3 | 114946 |
30
|
37 | 19 | 13 | 5 | 157043 |
35
|
42 | 25 | 18 | 6 | 211917 |
40
|
47 | 33 | 24 | 8 | 283103 |
We guarantee substantial savings, operational autonomy, and supply continuity.